DAISHIN INDUSTRIAL CO.,LTD.
COMPANY PROFILE NEWS
TOP PAGE
BRAZING MATERIAL &
EQUIPMENT
MACHINERY ENGINEERING
AUTOMATIC BRAZING MACHINES
GAS CONTROLER FLOTORN
INQUIRY
SITE MAP

FLOTRON (Intelligent Gas Controller)

FLOTRON is a gas controller that has a function, which keep the mixture rate of gas set beforehand. By using built-in mass flow controller; gas flow rate does not change and supply gas stability if primary side supplies pressure change.

Outline specification
Power source AC85 - AC264V (inner power voltage DC24V)
Power consumption under 75W
Memory of Flow ratio 10 (standard) 20/30 (option)
FLOTRON body 210(W)×590(D)×420(H)

  • A remote controlling graphic operation terminal is prepared as standard.
  • Mixture ratio stay if setting flow rate change.
  • 10/20/30 different gas mixture ratios and gas flow rates can be memorized.
  • Copy function of the brazing data is available.
  • Display function of integrating and cumulative flow rate.
  • Clogging with Vapour Flux is dissolved.
  • It is the best for aluminum brazing.
  •  Extinction by using nitrogen when blackout occurs.

♦Many functions can be operated with the graphic operation terminal (touch panel). The operations are very easy.♦
Operating screen Flow rate setting screen Integration flow rate display screen

♦When ordering brazing machine, it is possible to control only 1 operation screen.♦
When ordering automatic brazing machine, basically to control the gas is to use FLOTRON. In that case, adopt large touch panel to control board for machine, therefore the touch panel for FLOTRON side became no use. If the gas circuit was plural, it is only to shift the screen.
In addition, OHS is prepared for option.

♦OHS [Optimum Heating System].♦
The temperature of work or jig will change when beginning of operation or weather change etc. therefore, it was necessary to change setting of heating time or pre-heating operation the jig.
OHS will operate this annoying work in automatically. This system measure the work, which before heated or temperature of the jig and automatically change the setting of the heating time.
In other word, if the jig or work changes the temperature by circumstance, every time check the temperature and this system change the heating time.

The screen above shows the graph of measured temperature and setting time. On the graph, there are 6 line of [temperature setting axis] and choose with 6 light blue rectangular switch. The upper-right is [time up-down key] and changes the temperature by using up/down key. Automatically figure out the setting time on line graph to measuring temperature from a 6 dot, which is set.

BRAZING MATERIAL AND EQUIPMENT   |    MACHINERY ENGINEERING   |    INQUIRY   |    TOP PAGE
Copyright © 2005 DAISHIN INDUSTRIAL CO.,LTD. All Rights Reserved